TOP
Online Message
GE VMIACC-5595-208 350-805595-208N 2 Gb/s Reflective Memory Managed Hub Assembly

The GE VMIACC-5595-208 350-805595-208N is a 2 Gb/s Reflective Memory Managed Hub Assembly (also known as ACC-5595-208) from GE Fanuc Intelligent Platforms (now Abaco Systems). Designed to operate with the 5565 family of Reflective Memory real-time network products, the GE VMIACC-5595-208 350-805595-208N serves as a central hub that enables high-speed, deterministic data sharing across distributed nodes in VME, PCI, and other bus-independent systems.

Description
Product Case Introduction:

There are still some products that have not been listed yet. For more information, please contact us. If the product model does not match the displayed picture, the actual model shall prevail. Please consult us for specific product images; We will arrange for the warehouse to take photos for confirmation. We have 76 shared warehouses worldwide, so it may take several hours to accurately respond to your message. We deeply apologize for any inconvenience caused to you. Of course, we will process your inquiry as soon as possible.


The GE VMIACC-5595-208 350-805595-208N is a 2 Gb/s Reflective Memory Managed Hub Assembly (also known as ACC-5595-208) from GE Fanuc Intelligent Platforms (now Abaco Systems). Designed to operate with the 5565 family of Reflective Memory real-time network products, the GE VMIACC-5595-208 350-805595-208N serves as a central hub that enables high-speed, deterministic data sharing across distributed nodes in VME, PCI, and other bus-independent systems. The GE VMIACC-5595-208 350-805595-208N supports up to 8 ports using hot-pluggable SFP transceivers (multimode or single-mode fiber), allowing flexible configurations for short or long-distance links (up to 10 km). It features automatic node bypass on signal loss or synchronization failure, support for cascading up to 256 nodes, and advanced management via RS232 and Ethernet ports. The GE VMIACC-5595-208 350-805595-208N is housed in a compact 19" 1U rack-mount or desktop enclosure with a universal AC power supply, making it ideal for simulation, industrial automation, power generation, test systems, and real-time control applications requiring low-latency, high-reliability data replication. The GE VMIACC-5595-208 350-805595-208N enhances network fault tolerance and scalability while maintaining the deterministic performance critical for mission-critical environments.

VMIACC-5595-208 350-805595-208N


Key Parameters:

Model,GE VMIACC-5595-208 (350-805595-208N)

Manufacturer,GE Fanuc / Abaco Systems

Product Type,2 Gb/s Reflective Memory Managed Hub Assembly

Data Rate,2 Gb/s

Ports,"Up to 8 × SFP transceiver ports (multimode or single-mode fiber, LC connectors)"

Node Support,Cascading up to 256 nodes

Fault Tolerance,Automatic port/node bypass on loss of signal or invalid sync

Management Interfaces,"RS232 (front), Ethernet (RJ45 front)"

Enclosure,"19"" 1U rack-mount or desktop"

Power Supply,"Internal universal: 90–264 VAC, 47–440 Hz, ~25 W"

Fiber Distance,Configurable up to 10 km (single-mode)

Operating Temperature,0°C to +55°C (typical industrial range)

Additional Features,"Dark-on-Dark option, hot-pluggable SFPs, EMI dust plugs on unused ports, universal power inlet with fuse"

 VMIACC-5595-208 350-805595-208N

Operation Steps:

Mount the GE VMIACC-5595-208 350-805595-208N in a 19" rack or desktop location and secure with handles if rack-mounted.

Install required SFP transceivers (multimode or single-mode) into the front-panel ports; unused ports retain EMI dust plugs.

Connect duplex LC fiber optic cables between the hub ports and 5565 Reflective Memory nodes.

Connect the universal AC power cord to the rear IEC inlet and switch on the power.

Verify power LED and port status LEDs; use the front RS232 or Ethernet port for local management and configuration if needed.

Power up connected Reflective Memory nodes and confirm link synchronization and data replication via application software.

Monitor network health; the hub automatically bypasses faulty ports to maintain ring or star topology integrity.

Installation Precautions:

De-energize the hub and all connected Reflective Memory nodes before installing or removing SFPs or fiber cables to avoid eye damage from laser light or electrical hazards.

Use only approved SFP transceivers compatible with the 2 Gb/s Reflective Memory protocol; mix multimode and single-mode as needed for distance requirements.

Handle fiber optic cables carefully to prevent bending radius violations or connector contamination; clean LC connectors before mating.

Ensure proper grounding of the chassis and route fiber cables separately from high-voltage or EMI sources.

Verify the AC power source matches 90–264 VAC and that the rear fuse (typically 4A/250V) is intact before powering on.

Allow adequate ventilation around the 1U enclosure for proper cooling.

After installation, perform link tests and monitor bypass functionality by simulating a node failure to confirm automatic recovery.

Daily Maintenance Content Details:

Check front-panel LEDs on the GE VMIACC-5595-208 350-805595-208N daily for power status, link/activity on each SFP port, and any bypass indicators.

Monitor Reflective Memory network diagnostics via connected nodes or management software for synchronization errors or bypassed ports.

Inspect fiber connectors and cables weekly for dust, damage, or loose connections; clean with approved fiber optic tools if necessary.

Verify cabinet temperature and airflow to keep the hub within operating limits.

Review event logs or management interface (RS232/Ethernet) for any port faults or power anomalies.

Clean the enclosure vents and front panel (power off) using low-pressure compressed air every 1–3 months depending on environment.

Periodically test full network redundancy by disconnecting a fiber link and confirming automatic bypass and data continuity during scheduled maintenance.


Do you provide global shipping services?

Yes. We have local distribution centers on all continents, which can quickly transport parts to any corner of the world.

2. What payment methods and currencies do you accept?

To make your purchasing process as simple as possible, we offer multiple payment methods including bank transfer, check, and PayPal. Meanwhile, we also accept most mainstream credit and debit cards, such as Visa, Mastercard, and American Express. We can accept payments in most major currencies worldwide, but we recommend using US dollars (USD), British pounds (GBP), or euros (EUR) as a priority. Payments in other currencies may incur additional fees. All transactions are securely processed by HSBC Bank and HSBC Merchant Services.

How many parts do you currently have in stock?

We have a vast inventory of thousands of new, refurbished, and outdated automation components, including products from well-known manufacturers such as ABB and Schneider. If you cannot find the required parts, please do not worry. We work closely with a global network of professional suppliers to provide you with tailored quotes even if the part is not listed on our website.

Who can I contact if I encounter any problems?

Our experienced customer service team will handle any issues after you place your order.

Related Products
Guangzhou Qiming Automation Technology Co., Ltd
Room 208, Room D487, No.1933-20 Huaguan
Road, Tianhe District, Guangzhou City
WhatsApp
+86 16626708626
Email
3772179818@qq.com
WhatsApp
WeChat