The HIMA F8650E is a safety-related central processing module designed for HIMA HIQUAD safety control systems. As the core processing unit of the safety architecture, the F8650E performs safety logic execution, system coordination, diagnostics, and communication management for industrial automation applications.
Equipped with two clock-synchronized 32-bit microprocessors, the F8650E provides reliable and deterministic processing performance for safety-critical operations. It is widely applied in process industries where continuous monitoring, fault detection, and high system availability are required.
.jpg)
.jpg)
There are still some products that have not been listed yet. For more information, please contact us. If the product model does not match the displayed picture, the actual model shall prevail. Please consult us for specific product images; We will arrange for the warehouse to take photos for confirmation. We have 76 shared warehouses worldwide, so it may take several hours to accurately respond to your message. We deeply apologize for any inconvenience caused to you. Of course, we will process your inquiry as soon as possible.
The HIMA F8650E is a central CPU module developed for HIMA programmable electronic safety systems. It functions as the main control unit responsible for executing user safety programs, processing input information, controlling output responses, and managing communication between system components.
The module integrates two synchronized Intel 386EX 32-bit microprocessors operating at 25 MHz, providing redundant processing capability for safety-related applications. The F8650E includes Flash-EPROM memory for operating system and user programs, SRAM data storage, RS485 communication interfaces, and a diagnostic display for system status monitoring.
Designed for long-term industrial operation, the HIMA F8650E supports applications requiring dependable safety control, predictable response times, and efficient fault diagnostics.
| Parameter | Specification |
|---|---|
| Manufacturer | HIMA |
| Model | F8650E |
| Product Type | Central Processing Module |
| System Series | HIQUAD Safety System |
| Processor Type | 2 × INTEL 386EX 32-bit Microprocessors |
| Clock Frequency | 25 MHz |
| Processor Synchronization | Clock-Synchronized Operation |
| Operating System Memory | 1 MB Flash-EPROM |
| User Program Memory | 512 KB Flash-EPROM |
| Data Memory | 256 KB SRAM |
| Communication Interface | 2 × RS485 Serial Interfaces |
| Interface Isolation | Electrically Isolated |
| Diagnostic Display | 4 Digit Matrix Display |
| Watchdog Function | Safety Related Watchdog Output |
| Watchdog Output | 24 VDC |
| Maximum Watchdog Load | Up to 500 mA |
| Short Circuit Protection | Available |
| Power Supply | 5 VDC |
| Current Consumption | Approx. 2000 mA |
| Installation Space | 8 TE |
| Construction | Modular PCB Design |
.jpg)
.jpg)
The F8650E uses two synchronized microprocessors to improve processing reliability and support safety-related control applications.
The module provides stable and predictable program execution, making it suitable for applications where accurate response timing is essential.
Built-in diagnostic functions and display information help operators identify system status and simplify troubleshooting.
Two electrically isolated RS485 interfaces enable stable communication with connected safety system components.
The integrated safety watchdog function supports automatic fault response and improves overall system protection.
HIMA F8650E is commonly used in:
Safety Instrumented Systems (SIS)
Emergency Shutdown Systems (ESD)
Oil & Gas Processing Facilities
Petrochemical Plants
Power Generation Systems
Chemical Production Lines
Industrial Process Automation
Burner Management Systems
Critical Infrastructure Safety Control
The HIMA F8650E is a central processing module used to execute safety programs and control safety-related automation functions in HIMA systems.
The F8650E uses two clock-synchronized Intel 386EX 32-bit microprocessors with a 25 MHz clock frequency.
Yes. The module is designed for safety-related industrial control systems requiring reliable processing, diagnostics, and fault monitoring.
The F8650E provides two electrically isolated RS485 serial interfaces for system communication.
The F8650E is mainly used in HIMA HIQUAD safety systems for industrial process safety and automation applications.
Do you provide global shipping services?
Yes. We have local distribution centers on all continents, which can quickly transport parts to any corner of the world.
2. What payment methods and currencies do you accept?
To make your purchasing process as simple as possible, we offer multiple payment methods including bank transfer, check, and PayPal. Meanwhile, we also accept most mainstream credit and debit cards, such as Visa, Mastercard, and American Express. We can accept payments in most major currencies worldwide, but we recommend using US dollars (USD), British pounds (GBP), or euros (EUR) as a priority. Payments in other currencies may incur additional fees. All transactions are securely processed by HSBC Bank and HSBC Merchant Services.
How many parts do you currently have in stock?
We have a vast inventory of thousands of new, refurbished, and outdated automation components, including products from well-known manufacturers such as ABB and Schneider. If you cannot find the required parts, please do not worry. We work closely with a global network of professional suppliers to provide you with tailored quotes even if the part is not listed on our website.
Who can I contact if I encounter any problems?
Our experienced customer service team will handle any issues after you place your order.