The GE IS220PDOAH1A is a high-reliability Discrete Output I/O Pack (also known as PDOA or Contact Output Pack) engineered for the GE Speedtronic Mark VIe turbine control system. As a distributed I/O module, the GE IS220PDOAH1A interfaces directly with discrete output terminal boards (such as IS200TRLYH series, IS200SRLY series, etc.) to provide precise control of up to 12 relay outputs while monitoring coil feedback and status signals.


There are still some products that have not been listed yet. For more information, please contact us. If the product model does not match the displayed picture, the actual model shall prevail. Please consult us for specific product images; We will arrange for the warehouse to take photos for confirmation. We have 76 shared warehouses worldwide, so it may take several hours to accurately respond to your message. We deeply apologize for any inconvenience caused to you. Of course, we will process your inquiry as soon as possible.
The GE IS220PDOAH1A is a high-reliability Discrete Output I/O Pack (also known as PDOA or Contact Output Pack) engineered for the GE Speedtronic Mark VIe turbine control system. As a distributed I/O module, the GE IS220PDOAH1A interfaces directly with discrete output terminal boards (such as IS200TRLYH series, IS200SRLY series, etc.) to provide precise control of up to 12 relay outputs while monitoring coil feedback and status signals.
The GE IS220PDOAH1A is widely used in gas and steam turbine generator applications for actuating solenoids, breakers, alarms, interlocks, and auxiliary devices. It supports simplex or TMR (Triple Modular Redundant) configurations, connects to up to two IONet Ethernet networks, and delivers fast response times (approximately 6 ms from command to output). Its robust design, built-in diagnostics, and compatibility with multiple terminal board types make the GE IS220PDOAH1A essential for reliable discrete control in critical power generation environments. Whether used as a replacement or in new installations, the GE IS220PDOAH1A ensures seamless integration and high availability within the Mark VIe architecture.

Model,GE IS220PDOAH1A
Module Type,Discrete Output I/O Pack (PDOA / Contact Output Pack)
Relay Channels,Up to 12 relays (Form-C or solid-state depending on terminal board)
Output Ratings,"Varies by terminal board (e.g., 24/48/125 V DC, 120/240 V AC; currents up to 5–7 A per channel, total limited)"
Feedback,Coil sensing / relay status monitoring (up to 15 inputs monitored)
Response Time,Approx. 6 ms (Ethernet command to output)
Power Supply,"28 V DC nominal (27.4–28.6 V range, max current ~0.71 A)"
Communication,"Dual IONet Ethernet ports (100 Mbps full-duplex, RJ45)"
Operating Temperature,-40°C to +70°C (or wider depending on configuration)
Humidity,"5% to 95% RH, non-condensing"
Dimensions,Approx. 8.26 cm × 4.19 cm × 12.1 cm
Weight,Approx. 0.45–0.6 kg
Protections,"ESD, surge suppression, overvoltage, channel diagnostics"
Compatibility,"GE Speedtronic Mark VIe systems; works with TRLY, SRLY terminal boards (not DIN-rail DRLY)"

Operating the GE IS220PDOAH1A follows standard GE Mark VIe distributed I/O protocols:
Ensure the associated terminal board and control rack have stable 28 V DC power before system energization.
Mount the GE IS220PDOAH1A securely onto the discrete output terminal board and connect both IONet Ethernet cables (primary and secondary).
Initialize the Mark VIe controller and verify the GE IS220PDOAH1A I/O pack is detected and healthy via the HMI diagnostic screen.
Load the correct configuration file with proper relay mapping and feedback settings for the GE IS220PDOAH1A.
Monitor real-time relay command status, coil feedback, output health, and any alarms through the operator interface.
During normal turbine operation, the GE IS220PDOAH1A executes discrete output commands from the controller with high reliability.
In case of alarms, use built-in diagnostics to isolate issues specific to the GE IS220PDOAH1A and perform forced output tests when safe.
Proper installation of the GE IS220PDOAH1A is critical for system safety and performance. Always de-energize the entire control system and apply lockout/tagout procedures before handling. Use ESD-safe wrist straps and grounded workstations when attaching the GE IS220PDOAH1A to the terminal board. Align the pack carefully with the connectors on the terminal board and press firmly until fully seated and latched. Connect the three-pin power input and both RJ45 IONet ports using shielded Ethernet cables with proper strain relief. Ensure field wiring on the terminal board meets torque and wire gauge specifications for the selected relay ratings. After installing the GE IS220PDOAH1A, perform complete I/O loop checks, relay functional tests, coil feedback verification, and system diagnostics before commissioning the turbine. Only qualified technicians trained on GE Mark VIe systems should install or service the GE IS220PDOAH1A.
Routine maintenance helps maximize the reliability and service life of the GE IS220PDOAH1A:
Visually inspect the GE IS220PDOAH1A and its connections for dust, loose cables, or signs of overheating during scheduled outages.
Clean the exterior gently with dry compressed air — never use liquids or solvents on the module.
Review Mark VIe HMI diagnostic logs daily for I/O pack health, relay status, coil feedback, Ethernet link integrity, and any alarms related to the GE IS220PDOAH1A.
Verify 28 V DC power supply remains within the acceptable range and monitor current draw.
Check both IONet ports for active communication and low error rates.
Confirm relay outputs and feedback signals match commanded states during periodic tests.
Record any anomalies and schedule professional inspection, firmware updates, or pack replacement annually to sustain the high performance of the GE IS220PDOAH1A.
Do you provide global shipping services?
Yes. We have local distribution centers on all continents, which can quickly transport parts to any corner of the world.
2. What payment methods and currencies do you accept?
To make your purchasing process as simple as possible, we offer multiple payment methods including bank transfer, check, and PayPal. Meanwhile, we also accept most mainstream credit and debit cards, such as Visa, Mastercard, and American Express. We can accept payments in most major currencies worldwide, but we recommend using US dollars (USD), British pounds (GBP), or euros (EUR) as a priority. Payments in other currencies may incur additional fees. All transactions are securely processed by HSBC Bank and HSBC Merchant Services.
How many parts do you currently have in stock?
We have a vast inventory of thousands of new, refurbished, and outdated automation components, including products from well-known manufacturers such as ABB and Schneider. If you cannot find the required parts, please do not worry. We work closely with a global network of professional suppliers to provide you with tailored quotes even if the part is not listed on our website.
Who can I contact if I encounter any problems?
Our experienced customer service team will handle any issues after you place your order.