The Woodward 5501-365 is a field-termination network interface module purpose-built for high-availability MicroNet Triple Modular Redundant (TMR) control topologies. Designed to complement high-density I/O setups, this robust module acts as a secure landing area for mission-critical Magnetic Pickup (MPU) speed sensors, analog inputs, and field actuators. It handles crucial signaling transitions between severe engine room environments and centralized processor racks without compromising loop speed or noise rejection.
.jpg)
.jpg)
There are still some products that have not been listed yet. For more information, please contact us. If the product model does not match the displayed picture, the actual model shall prevail. Please consult us for specific product images; We will arrange for the warehouse to take photos for confirmation. We have 76 shared warehouses worldwide, so it may take several hours to accurately respond to your message. We deeply apologize for any inconvenience caused to you. Of course, we will process your inquiry as soon as possible.
The Woodward 5501-365 functions as a highly reliable, high-density connection layer within the Woodward MicroNet and MicroNet Plus industrial control platforms. Specifically tailored to handle the hardware routing requirements of TMR (Triple Modular Redundant) system frameworks, this interface simplifies the wiring of essential engine and turbine governance equipment.
By operating alongside the 5466-253 TMR Combo I/O motherboard, the 5501-365 splits or aggregates critical real-time speed values and high-accuracy valve driver parameters. The card relies on robust physical barrier strips to ground unwanted noise from incoming lines, safeguarding sensitive control dynamics during extreme engine start-ups and sudden load variations.
| Parameter Attribute | Engineering Specifications / Ratings |
| Manufacturer | Woodward Governor Company |
| Part Number (P/N) | 5501-365 |
| Compatible Platform | MicroNet TMR / MicroNet Plus |
| Associated I/O Board | 5466-253 TMR Combo Module |
| Cabling Group | Table J Interface Cabling |
| Speed Sensor Capacity | 4 x Dedicated Magnetic Pickup (MPU) Channels |
| Analog Inputs | 8 x Channels (Configured for 0-5 Vdc Signal Ranges) |
| Analog Outputs | 4 x Channels (Isolated 4-20 mA Outputs) |
| Actuator Drive Support | 2 x Proportional Actuator Control Lines |
| Maximum Rated Voltage | 24 Vdc Industrial Range |
| Operating Envelope | Full industrial temperature range (-40°C to +85°C) |
.jpg)
.jpg)
Optimized High-Speed MPU Tracking: Processes four independent speed sensor feeds simultaneously to allow immediate cross-checks for overspeed or sensor failure conditions.
TMR Architecture Ready: Built explicitly to support hardware voting lines, preventing single points of failure from tripping the turbine or prime mover.
Low-Impedance Analog Paths: Maintains zero-degradation tracking on 0-5V voltage lines and standard 4-20mA loop signals over dense industrial wiring tracts.
Hardened Form Factor: Protects electrical paths against severe thermal fluctuations and mechanical vibration common near heavy steam machinery and turbine skids.
Streamlined Maintenance Routing: Allows easy field swapping or troubleshooting of connection groups without altering core chassis logic or main system wiring loops.
Triple Modular Redundant Governors: Used on critical power generation turbine systems demanding zero-downtime performance.
Hydroelectric Power Stations: Manages proportional actuator controls on primary water gates and guide vanes.
Large Bore Diesel Engines: Directs high-accuracy magnetic pickup speed signals back to tracking registers for locomotive or marine propulsion setups.
Q1: Which interconnect cable type must be used to link the 5501-365 to the main MicroNet rack?
A: The 5501-365 is matched to the system through Woodward’s standardized Table J cable configurations, linking it straight to the 5466-253 TMR combo module.
Q2: Can I inject 4-20 mA current signals directly into the 0-5V voltage inputs?
A: No, the 8 primary inputs are calibrated for 0-5 Vdc voltage scales. To run 4-20mA inputs, external dropping resistors or an alternative termination assembly tailored for current loops must be used.
Q3: Does this module require an independent external 24V power supply to run?
A: No, the module draws its operating reference voltages directly through the system interface cable connected to the main active MicroNet chassis backplane.
Do you provide global shipping services?
Yes. We have local distribution centers on all continents, which can quickly transport parts to any corner of the world.
2. What payment methods and currencies do you accept?
To make your purchasing process as simple as possible, we offer multiple payment methods including bank transfer, check, and PayPal. Meanwhile, we also accept most mainstream credit and debit cards, such as Visa, Mastercard, and American Express. We can accept payments in most major currencies worldwide, but we recommend using US dollars (USD), British pounds (GBP), or euros (EUR) as a priority. Payments in other currencies may incur additional fees. All transactions are securely processed by HSBC Bank and HSBC Merchant Services.
How many parts do you currently have in stock?
We have a vast inventory of thousands of new, refurbished, and outdated automation components, including products from well-known manufacturers such as ABB and Schneider. If you cannot find the required parts, please do not worry. We work closely with a global network of professional suppliers to provide you with tailored quotes even if the part is not listed on our website.
Who can I contact if I encounter any problems?
Our experienced customer service team will handle any issues after you place your order.