The PQMII-T20 power quality meter serves as a robust endpoint for monitoring power networks in high-interference environments. It bridges high-voltage physical assets with digital management networks by recording line data at a microscopic level. It tracks high-frequency harmonics and voltage spikes, translating raw electrical data into practical maintenance insights. The layout fits standard DIN cuts, allowing easy retrofitting into existing switchgear cubicles.

Description
Case Introduction:

There are still some products that have not been listed yet. For more information, please contact us. If the product model does not match the displayed picture, the actual model shall prevail. Please consult us for specific product images; We will arrange for the warehouse to take photos for confirmation. We have 76 shared warehouses worldwide, so it may take several hours to accurately respond to your message. We deeply apologize for any inconvenience caused to you. Of course, we will process your inquiry as soon as possible.


GE PQMII-T20 Power Quality Metering and Diagnostic System

The GE Multilin PQMII-T20 functions as a multi-functional, digital power monitoring tool designed to replace an array of traditional analog meters, transducers, and chart recorders. This microprocessor-driven apparatus tracks three-phase voltage and current inputs simultaneously, computing true RMS values for active, reactive, and apparent power metrics. By prioritizing the "T20" hardware configuration, this specific version guarantees integrated 4-20mA analog outputs, allowing direct connection to supervisory control loops without needing external signal-conditioning modules.

Beyond basic electrical metering, the system features specialized diagnostic tools that analyze underlying power quality parameters. It evaluates phase angle deviations, line frequency variations, and current unbalance patterns that could indicate internal winding damage in downstream induction machinery. The front panel features a bright vacuum fluorescent display, giving substation mechanics immediate access to diagnostic screens under any lighting condition.

PQMII-T20


Technical Parameters:
Technical Evaluation NodeMeasured Engineering Limits & Standard Profiles
Transducer Interfacing (T20)4 fully isolated 4-20mA analog channels for direct parameter streaming.
Transient Disturbance LogDeep waveform capturing capability optimized for transient sag/swell profiling.
Voltage Sensing EnvelopeDirect input connection up to 600 VAC line-to-line without requiring external PTs.
Current Circuit BurdenMinimal internal CT circuit loading ensuring loop accuracy remains uncompromised.
Total Harmonic AnalysisCalculations extended up to the 31st harmonic for thorough line health checks.
Relay Output MappingThree independent programmable form-C dry contacts for localized alarm triggering.

 PQMII-T20


Core Advantages & Key Design Attributes:
  • Integrated Signal Conversion: Eliminates the cost of separate current-to-analog converters by using built-in 4-20mA channels.

  • Detailed Event Sequencing: Tracks precise event logs with 1-millisecond time-stamping accuracy to determine the sequence of grid failures.

  • Advanced Harmonic Tracking: Prevents harmonic resonance and capacitor bank failure by constantly checking THD indices.

  • Flexible Logic Output Control: Allows the programming of localized output relays to op

Installation Precautions:
  • Integrated Signal Conversion: Eliminates the cost of separate current-to-analog converters by using built-in 4-20mA channels.

  • Detailed Event Sequencing: Tracks precise event logs with 1-millisecond time-stamping accuracy to determine the sequence of grid failures.

  • Advanced Harmonic Tracking: Prevents harmonic resonance and capacitor bank failure by constantly checking THD indices.

  • Flexible Logic Output Control: Allows the programming of localized output relays to open circuit breakers during critical overvoltage events.

Operational Application Fields:

The PQMII-T20 monitoring platform is purpose-built for continuous deployment across major electrical environments, specifically:

  • Industrial Peak-Demand Management: Assisting plant facility managers in evaluating power factor penalization risks and load-shedding scheduling.

  • Critical Incomer Panel Monitoring: Acting as the main diagnostic window for heavy-duty main breaker enclosures in automated factories.

  • Motor Control Center (MCC) Upstream Auditing: Capturing transient voltage drops caused by the across-the-line starting of high-horsepower industrial motors.

  • Sub-Metering and Cost Allocation: Delivering high-accuracy revenue-grade energy calculation data within multi-tenant industrial parks.

FAQ:
  • Q1: What are the specific capabilities of the four analog outputs on the T20 model?

    • A1: The four 4-20mA outputs are fully programmable using the front keypad or software. They can be assigned to represent parameters like Voltage, Current, kW, or Total Harmonic Distortion.

  • Q2: Does this unit require a potential transformer (PT) for medium-voltage lines?

    • A2: Yes. While it can handle up to 600 VAC directly, it needs standard potential transformers scaled to its input limits for medium- or high-voltage lines.

  • Q3: How does the waveform capture tool assist with system diagnostics?

    • A3: When a set threshold is crossed, the PQMII-T20 captures the exact waveform shape. This helps field technicians differentiate between external utility supplier faults and internal equipment failures.


Do you provide global shipping services?

Yes. We have local distribution centers on all continents, which can quickly transport parts to any corner of the world.

2. What payment methods and currencies do you accept?

To make your purchasing process as simple as possible, we offer multiple payment methods including bank transfer, check, and PayPal. Meanwhile, we also accept most mainstream credit and debit cards, such as Visa, Mastercard, and American Express. We can accept payments in most major currencies worldwide, but we recommend using US dollars (USD), British pounds (GBP), or euros (EUR) as a priority. Payments in other currencies may incur additional fees. All transactions are securely processed by HSBC Bank and HSBC Merchant Services.

How many parts do you currently have in stock?

We have a vast inventory of thousands of new, refurbished, and outdated automation components, including products from well-known manufacturers such as ABB and Schneider. If you cannot find the required parts, please do not worry. We work closely with a global network of professional suppliers to provide you with tailored quotes even if the part is not listed on our website.

Who can I contact if I encounter any problems?

Our experienced customer service team will handle any issues after you place your order.

Related Products
Guangzhou Qiming Automation Technology Co., Ltd
Room 208, Room D487, No.1933-20 Huaguan
Road, Tianhe District, Guangzhou City
WhatsApp
+86 16626708626
Email
3772179818@qq.com
WhatsApp
WeChat