16CH Group-isolated Sourcing Output: All 16 channels integrated into one isolation group, group-wise ground isolation with 500VAC dielectric withstand, output voltage range 19.2~32VDC, rated continuous 0.5A per channel.
Full Safety Grade Certification: IEC61508 SIL3 + EN954-1 Category4 approval, output driver fault tolerance=1, ND(Normally De-energized) safety loop keeps controllable under partial hardware failure.
Intelligent Full-loop Diagnostics: Built-in open-load/short-circuit loop monitoring with configurable threshold; diagnose switch status without output pulse disturbance; front panel RUN/FAULT/WARN + per-channel LED status indicator for rapid fault pinpoint.
Multi-layer Circuit Protection: Per-channel over-current limiting, automatic over-temperature shutdown, built-in inductive load surge suppression & EMC filter, avoid burnout from field wrong wiring or surge impact.
Hot-swap & Modulebus Communication: Direct plug into S800 I/O rack, communicate with AC800M controller via backplane Modulebus; support online hot replacement without rack power cut, system auto-address identification after installation.
Degraded Operation Mode: From PR:G revision onwards, normally energized channels keep partial running when individual channel fails, reduce full system shutdown risk.
_副本.jpg)
_副本.jpg)
There are still some products that have not been listed yet. For more information, please contact us. If the product model does not match the displayed picture, the actual model shall prevail. Please consult us for specific product images; We will arrange for the warehouse to take photos for confirmation. We have 76 shared warehouses worldwide, so it may take several hours to accurately respond to your message. We deeply apologize for any inconvenience caused to you. Of course, we will process your inquiry as soon as possible.
As core safety control spare of ABB S800 I/O & System800xA SIS system, DO880 solves common site faults: safety valve fail to trip on interlock signal, relay no action with DCS output command, frequent channel overload alarm, intermittent output missing caused by driver aging or surge damage. Fully consistent with OEM dimension, pin definition and terminal wiring, direct one-to-one swap replacement without modifying safety logic program and field cable layout, minimize unplanned plant shutdown loss during emergency maintenance.
_副本.jpg)
| Item | Specification |
|---|---|
| Model/PN | DO880 / 3BSE028602R1 |
| Applicable System | ABB System800xA, AC800M, S800 I/O Rack Series |
| Origin | Sweden ABB Original Factory |
| Channel Count | 16CH Group Isolated Digital Output |
| Output Type | 24VDC Current Sourcing(19.2~32VDC) |
| Rated Output Current | 0.5A per single channel |
| Safety Certification | IEC61508 SIL3, EN954-1 Category4 |
| Isolation Spec | Group isolated from ground, 500VAC Withstand Voltage |
| Max Field Cable Length | 600m per channel |
| Max Full-load Power Dissipation | 5.6W |
| Modulebus Power Draw | +5V:45mA; +24V Modulebus:Max50mA; External24V:10mA |
| PCB Protection | Conformal Coating for G3 harsh corrosive environment |
| Operating Temp | -20℃ ~ +60℃ |
| Storage Temp | -40℃ ~ +70℃ |
| Ambient Humidity | 5%~95%RH Non-condensing |
| Dimension(W×H×D) | 45×119×102mm |
| Net Weight | ≈0.2kg |
| Protection Grade | IP20(Cabinet Inner Mount) |
| Certification | CE, UL, cUL, RoHS |
| MTBF | >950,000 Working Hours |
_%E5%89%AF%E6%9C%AC.jpg)
Thermal Power Plant: Boiler fuel shut-off valve, turbine emergency trip solenoid safety interlock control spare
Petrochemical & Refinery: Reactor emergency isolation valve, flare system trip relay SIS cabinet spare parts
Chemical Industry: Toxic gas cut-off valve, hazardous process safety shutdown DO spare inventory
Pulp & Paper Factory: High-temperature oven emergency stop actuator, fire suppression interlock control module
Oil & Gas Plant: Pipeline emergency shut-down valve, compressor safety trip control spare
SIL3 High Safety Level: Perfect match for SIS safety instrument system, satisfy global petrochemical safety standard requirement
Full-channel Loop Diagnosis: Auto detect open/short circuit, drastically cut field troubleshooting time
Integrated Surge Suppression: No extra external flywheel diode needed for inductive load like solenoid/relay, simplify wiring
Single & Redundant Dual Configuration: Flexible rack layout for high-availability safety projects
Hot-swap Quick Maintenance: No cabinet power off needed for module replacement, lower production downtime cost
New & Refurbished Dual Stock: Separate inventory for new project tender and on-site sudden emergency breakdown
Strict Pre-ship QC: Every unit completes full-range output loading test + communication verification before outgoing shipment
Do you provide global shipping services?
Yes. We have local distribution centers on all continents, which can quickly transport parts to any corner of the world.
2. What payment methods and currencies do you accept?
To make your purchasing process as simple as possible, we offer multiple payment methods including bank transfer, check, and PayPal. Meanwhile, we also accept most mainstream credit and debit cards, such as Visa, Mastercard, and American Express. We can accept payments in most major currencies worldwide, but we recommend using US dollars (USD), British pounds (GBP), or euros (EUR) as a priority. Payments in other currencies may incur additional fees. All transactions are securely processed by HSBC Bank and HSBC Merchant Services.
How many parts do you currently have in stock?
We have a vast inventory of thousands of new, refurbished, and outdated automation components, including products from well-known manufacturers such as ABB and Schneider. If you cannot find the required parts, please do not worry. We work closely with a global network of professional suppliers to provide you with tailored quotes even if the part is not listed on our website.
Who can I contact if I encounter any problems?
Our experienced customer service team will handle any issues after you place your order.