TOP
Online Message
GE 350-E-P1-G1-H-E-S-C-P-2E-D-N compact, cost-effective feeder protection relay (Intelligent Electronic Device, IED)

The GE 350-E-P1-G1-H-E-S-C-P-2E-D-N (Multilin™ 350 series) is a compact, cost-effective feeder protection relay (Intelligent Electronic Device, IED) from GE Vernova's Multilin 3 Series platform. The GE 350-E-P1-G1-H-E-S-C-P-2E-D-N provides primary or backup protection, control, metering, and monitoring for overhead lines, cable feeders, and related applications in low, medium, and high-voltage distribution networks (radial, looped, or meshed, with or without distributed generation). 

Description

There are still some products that have not been listed yet. For more information, please contact us. If the product model does not match the displayed picture, the actual model shall prevail. Please consult us for specific product images; We will arrange for the warehouse to take photos for confirmation. We have 76 shared warehouses worldwide, so it may take several hours to accurately respond to your message. We deeply apologize for any inconvenience caused to you. Of course, we will process your inquiry as soon as possible.


The GE 350-E-P1-G1-H-E-S-C-P-2E-D-N (Multilin™ 350 series) is a compact, cost-effective feeder protection relay (Intelligent Electronic Device, IED) from GE Vernova's Multilin 3 Series platform. The GE 350-E-P1-G1-H-E-S-C-P-2E-D-N provides primary or backup protection, control, metering, and monitoring for overhead lines, cable feeders, and related applications in low, medium, and high-voltage distribution networks (radial, looped, or meshed, with or without distributed generation). The GE 350-E-P1-G1-H-E-S-C-P-2E-D-N offers intuitive setup via front-panel HMI or EnerVista software, advanced communications (IEC 61850, Modbus, DNP3), programmable LEDs, and enhanced security features. The GE 350-E-P1-G1-H-E-S-C-P-2E-D-N excels in utility and industrial substations for fast fault detection (overcurrent, earth-fault, etc.), breaker control, and system reliability. The GE 350-E-P1-G1-H-E-S-C-P-2E-D-N supports drawout/non-drawout designs for easy maintenance. Overall, the GE 350-E-P1-G1-H-E-S-C-P-2E-D-N is a reliable, feature-rich feeder management solution for modern distribution systems.

350-E-P1-G1-H-E-S-C-P-2E-D-N


Key Parameters:

Model / Catalog Number,350-E-P1-G1-H-E-S-C-P-2E-D-N (Multilin 350 Feeder Protection Relay)

Device Type,Feeder Protection and Control IED

Power Supply,Low range (typically 24–48 V DC or similar; confirm per variant; many 350 models support wide 24–250 V DC / 100–240 V AC)

Current Inputs,1 A nominal (standard CT inputs; phase + ground)

Voltage Inputs,"Yes (for directional elements, metering, synchro-check if configured)"

Faceplate / HMI,"Enhanced faceplate (E) with LCD, full menu navigation, programmable LEDs"

Protection Functions (typical),"Overcurrent (50/51 phases/ground/neutral), directional/non-directional earth-fault, negative-sequence (46), breaker failure (50BF), thermal overload (49), voltage elements (27/59), frequency (81), arc flash (optional), auto-reclose, synchro-check"

Control & I/O,"Breaker control (close/trip), multiple digital inputs/outputs, trip/close supervision"

Communication,"Ethernet (IEC 61850 Ed.2, Modbus TCP, DNP3), serial options; advanced protocols"

Case / Mounting,Drawout design (common for easy testing/replacement)

Operating Temperature,-40 °C to +60 °C (industrial/extended range typical)

Additional Features,"Metering (currents, voltages, power, energy), event/disturbance recording, programmable logic, cybersecurity (role-based access, audit trails)"

Country of Origin,Canada (typical GE Multilin)

Life Cycle Status,"Active (ongoing support, spares, firmware updates)"

 350-E-P1-G1-H-E-S-C-P-2E-D-N


Operation Steps :

Mount the GE 350-E-P1-G1-H-E-S-C-P-2E-D-N in a panel/rack (drawout case slides into cradle); ensure grounding and ventilation.

Connect auxiliary power (verify range) and check power-up LEDs/HMI for normal status on the GE 350-E-P1-G1-H-E-S-C-P-2E-D-N.

Wire CT/VT inputs (phase/ground currents, voltages) and binary I/O (trip/close, alarms, controls) per polarity and diagram.

Set up communications (Ethernet/serial) to SCADA/substation network.

Use EnerVista 350 software or front HMI: configure protection settings (curves, pickup levels), CT/VT ratios, logic, and communications for the GE 350-E-P1-G1-H-E-S-C-P-2E-D-N.

Commission: perform secondary injection tests (overcurrent/earth-fault timing), verify breaker control, and run end-to-end fault simulation.

Monitor via HMI or EnerVista: check measurements, events, faults, and alarms during live operation with the GE 350-E-P1-G1-H-E-S-C-P-2E-D-N.

 350-E-P1-G1-H-E-S-C-P-2E-D-N

Installation Precautions :

Only qualified substation protection personnel should install/commission the GE 350-E-P1-G1-H-E-S-C-P-2E-D-N, following GE Vernova safety guidelines and IEC/IEEE standards.

Isolate power/CT circuits, lock out/tag out, short CT secondaries, discharge energy, and confirm zero voltage before wiring or handling the GE 350-E-P1-G1-H-E-S-C-P-2E-D-N.

Use shielded/twisted-pair cables for analogs, single-point shield grounding, and fiber/Ethernet for comms to minimize EMI.

Verify CT/VT polarity/ratios/burden; never open CT circuits when energized to avoid hazards.

Comply with environmental limits (temperature, humidity, vibration) and avoid unauthorized modifications for the GE 350-E-P1-G1-H-E-S-C-P-2E-D-N.

For directional or sensitive elements, confirm correct polarization and settings.

Daily Maintenance Content:

Check front HMI LEDs/display and status indicators on the GE 350-E-P1-G1-H-E-S-C-P-2E-D-N each shift for alarms, healthy status, or comms issues.

Monitor measured values (currents/voltages/power), protection quantities, and event logs via HMI or EnerVista for anomalies.

Inspect enclosure, cabling, and terminals for tightness, corrosion, dust, or damage impacting the GE 350-E-P1-G1-H-E-S-C-P-2E-D-N.

Verify time synchronization (if used) and communication links (IEC 61850 GOOSE, DNP3 polling) remain stable.

Clean ventilation/HMI screen (power off if needed) to prevent overheating or visibility issues on the GE 350-E-P1-G1-H-E-S-C-P-2E-D-N.

Review disturbance/fault records and self-supervision logs periodically; backup configuration/settings routinely.

During planned outages, perform injection tests on key protections (overcurrent/earth-fault) and contact GE Vernova support for firmware updates or diagnostics on the GE 350-E-P1-G1-H-E-S-C-P-2E-D-N.


Do you provide global shipping services?

Yes. We have local distribution centers on all continents, which can quickly transport parts to any corner of the world.

2. What payment methods and currencies do you accept?

To make your purchasing process as simple as possible, we offer multiple payment methods including bank transfer, check, and PayPal. Meanwhile, we also accept most mainstream credit and debit cards, such as Visa, Mastercard, and American Express. We can accept payments in most major currencies worldwide, but we recommend using US dollars (USD), British pounds (GBP), or euros (EUR) as a priority. Payments in other currencies may incur additional fees. All transactions are securely processed by HSBC Bank and HSBC Merchant Services.

How many parts do you currently have in stock?

We have a vast inventory of thousands of new, refurbished, and outdated automation components, including products from well-known manufacturers such as ABB and Schneider. If you cannot find the required parts, please do not worry. We work closely with a global network of professional suppliers to provide you with tailored quotes even if the part is not listed on our website.

Who can I contact if I encounter any problems?

Our experienced customer service team will handle any issues after you place your order.

Related Products
Guangzhou Qiming Automation Technology Co., Ltd
Room 208, Room D487, No.1933-20 Huaguan
Road, Tianhe District, Guangzhou City
WhatsApp
+86 16626708626
Email
3772179818@qq.com
WhatsApp
WeChat